Information for bremer Customer Service / Table of contents / indexDimensions, table cut-outsOperating instructionsAdjustments prior to operationRemov
CService instructions bremer VIVA, issued 1997-07 Status: 2003-03NNTC temperature sensor, 6-36Checking/replacing, 6-37Operation/graph, 6-36OOpening th
10-12Service instructions bremer VIVA, issued 1997-07 Status: 2003-0310.6 Completion of Service-Menu − control board II (2cd gen.)Guilty for the breme
10-13Service instructions bremer VIVA, issued 1997-07 Status: 2003-03. By pressing the key to menue“Brita Mode”.You can adjust the predeterminingco
10-14Service instructions bremer VIVA, issued 1997-07 Status: 2003-03. Go to “Menü verlassen” (Exitmenu) with key . Confirm the setting with key The m
10-15Service instructions bremer VIVA, issued 1997-07 Status: 2003-03Presetting Counter = 6000 literPresetting operation mode = 0operation mode 0 = no
10-16Service instructions bremer VIVA, issued 1997-07 Status: 2003-0310.9 Software to the new PC board, PlugIn (Version II)Download of the new Softwar
10-17Service instructions bremer VIVA, issued 1997-07 Status: 2003-03How to make a download to the PCb:With Alex you communicate via the LON Network.C
10-18Service instructions bremer VIVA, issued 1997-07 Status: 2003-03PlugIn − descriptioninform.windowadjust equipment versioninformationwindowSelect
10-19Service instructions bremer VIVA, issued 1997-07 Status: 2003-0310.10Short instructions for cleaning the milkpipe and brewing unitA) Cleaning of
10-20Service instructions bremer VIVA, issued 1997-07 Status: 2003-03Remove the jug with the detergentsolutuin.Fill approx. 1 litre ofclear COLD water
10-21Service instructions bremer VIVA, issued 1997-07 Status: 2003-03Clean the dispenser block daily with the detergent BREMIL in order to ensure the
DService instructions bremer VIVA, issued 1997-07 Status: 2003-03Special tools/lubricants, 9-3Structural components, 6-1TTable cut−outs, 2-3HW Steam b
10-22Service instructions bremer VIVA, issued 1997-07 Status: 2003-035.) Insert the dispenser block,cover, coffeeoutlet into acleaning bath− approx. 2
10-23Service instructions bremer VIVA, issued 1997-07 Status: 2003-0310.11Functional Description VIVA au lait, Type 810 . . .Functional DescriptionThe
10-24Service instructions bremer VIVA, issued 1997-07 Status: 2003-03Flow chart: ”milk foam”Y5 steam IY8 steam IIY7 airpumpY9 rinse1sec1sec3 sectOpera
10-25Service instructions bremer VIVA, issued 1997-07 Status: 2003-03Flow chart: ”milk”Y5 steam IY8 steam IIY7 airpumpY9 rinse1sec2sec1sec1sec1sec1sec
10-26Service instructions bremer VIVA, issued 1997-07 Status: 2003-03Operation diagramme: ”free blisters of the milk line”boilerSteam withmilk remaind
10-27Service instructions bremer VIVA, issued 1997-07 Status: 2003-03Photo documentation VIVA au lait type 810. . .Illustration: VIVA au lait, right s
10-28Service instructions bremer VIVA, issued 1997-07 Status: 2003-03Photo documentationVIVA au lait type 810 . . ., Milk refrigerator with 1 pumpPump
10-29Service instructions bremer VIVA, issued 1997-07 Status: 2003-03Photo documentationVIVA au lait type 810 . . ., Milkfridge with 1 pumpIllustratio
10-30Service instructions bremer VIVA, issued 1997-07 Status: 2003-0310.12Functional description VIVA au lait, type 807, 813 . . .Functional descripti
10-31Service instructions bremer VIVA, issued 1997-07 Status: 2003-03Functional Diagram: “Milk foam” (Viva au lait)AirAir nozzleAir valveVentilationbo
2-1Service instructions bremer VIVA, issued 1997-07 Status: 2003-032. Dimensions, table cut−outs2.1 Outer dimensionsFront viewWatersoftenerCoffeeconta
10-32Service instructions bremer VIVA, issued 1997-07 Status: 2003-03Functional Diagram: “Milk” (Viva au lait)Air nozzleAir valveVentilationboilerMilk
10-33Service instructions bremer VIVA, issued 1997-07 Status: 2003-03Functional Diagram: “Milk” (Viva au lait with milk refrigerator)Pump 1boilerMilkY
10-34Service instructions bremer VIVA, issued 1997-07 Status: 2003-03Functional diagram: “blowing out the milk pipe”boilerSteam withmilk resi-dueY9M
10-35Service instructions bremer VIVA, issued 1997-07 Status: 2003-03Photo Documentation bremer Viva au laitFig. Viva au lait, right side:steam valve
10-36Service instructions bremer VIVA, issued 1997-07 Status: 2003-03bremer Viva au lait − milk refrigerator with two milk containersFig. Viva au lait
10-37Service instructions bremer VIVA, issued 1997-07 Status: 2003-0310.13Description of function VIVA Barista, type 807 . . .Description of functionT
10-38Service instructions bremer VIVA, issued 1997-07 Status: 2003-033. Dispenser for steam: Like standard VIVAExceptions:Second temperature sensor i
10-39Service instructions bremer VIVA, issued 1997-07 Status: 2003-03Design assembly: steam pipe with sensor, Ident. no. 730971Function of Steam dispe
Franke bremer GmbHLindenweg 36-42D-97999 IgersheimPhone: +49 7931 992 0Fax: +49 7931 517 00www.franke−cs.comService Manualbremer VIVA CoffeemachineE
2-2Service instructions bremer VIVA, issued 1997-07 Status: 2003-03Side viewCut−outs possible on both sides for routing connections.5050min.7040min.20
2-3Service instructions bremer VIVA, issued 1997-07 Status: 2003-032.2 Table cut−outsTable cut−outfor water inlet/outlet pipes andconnectingcable d=80
3-1Service instructions bremer VIVA, issued 1997-07 Status: 2003-033. Operating instructionsOperating instructions bremer VIVA in German, identity no.
4-1Service instructions bremer VIVA, issued 1997-07 Status: 2003-034. Adjustments prior to operation4.1 Setting the coffee quality (till Software-Vers
4-2Service instructions bremer VIVA, issued 1997-07 Status: 2003-034.2 Standard settings (since Software-Version 3.02)VIVA Standard factory setting wi
4-3Service instructions bremer VIVA, issued 1997-07 Status: 2003-03VIVA Standard - Notes for customer’s settingsArticle Grin-derleftcentrerightGrinder
4-4Service instructions bremer VIVA, issued 1997-07 Status: 2003-03VIVA au lait − without adjustable milk dosage − factory settingArticle Grin-derle
Service Manualbremer VIVA
4-5Service instructions bremer VIVA, issued 1997-07 Status: 2003-03VIVA au lait − without adjustable milk dosage − customer’s settingsArticle Grin-de
4-6Service instructions bremer VIVA, issued 1997-07 Status: 2003-03VIVA au lait − with adjustable milk dosage − factory settingArticle Grinderleftcent
4-7Service instructions bremer VIVA, issued 1997-07 Status: 2003-03VIVA au lait − with adjustable milk dosage − customer’s settingsArticle Grin-derle
4-8Service instructions bremer VIVA, issued 1997-07 Status: 2003-03Hot milkBrewing temperature: Pump pressure:Grounds container capacity:Steam boiler
4-9Service instructions bremer VIVA, issued 1997-07 Status: 2003-03VIVA Barista − factory setting (Vers. 1.0)Article GrinderleftcentrerightGrinderlock
4-10Service instructions bremer VIVA, issued 1997-07 Status: 2003-03VIVA Barista − customer’s settingsArticle GrinderleftcentrerightGrinderlockingposi
4-11Service instructions bremer VIVA, issued 2004−3VIVA TRAIN COOL With 2 Grinders − Factory Setting (Type 984329)Article Grin-derleftcentrerightGrin-
4-12Service instructions bremer VIVA, issued 2004−3VIVA TRAIN COOL With 2 Grinders − Notes For Customer’s SettingsArticle Grin-derleftcentrerightGrin-
5-1Service instructions bremer VIVA, issued 1997-07 Status: 2003-035. Removing the housing5.1 Opening ”upper front panel” / removing ”lower front pane
5-2Service instructions bremer VIVA, issued 1997-07 Status: 2003-03Removing the ”lower front panel”. Push up dispenser block.. Remove filler plug.. Re
These service instructions are intended for authorised bremer Cu-stomer Service staff only!The adjustments, repairs and maintenance work described in
5-3Service instructions bremer VIVA, issued 1997-07 Status: 2003-035.2 Removing the left / right−hand side sectionBefore removing the side sections, o
5-4Service instructions bremer VIVA, issued 1997-07 Status: 2003-035.4 Removing the bean containerBefore removing the bean container, open the upper f
5-5Service instructions bremer VIVA, issued 1997-07 Status: 2003-035.6 Removing the container ejection coverBefore removing the container ejection cov
6-1Service instructions bremer VIVA, issued 1997-07 Status: 2003-036. Structural components6.1 Coffee grinderThe service life of the grinding wheels i
6-2Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.1.2 Weighing the ground coffeeWeighing without dismounting the housingPlease note
6-3Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.1.4 Replacing the grinding wheelsReplace the grinding wheels:- after approx. 80.0
6-4Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.1.5 Technical data of coffee grinder motorVoltage: 230 V AC 50 Hz ⇒⇒⇒⇒ Nominal ou
6-5Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.2 Brewing unit6.2.1 Operation of brewing unitCalibration processThe brewing group
6-6Service instructions bremer VIVA, issued 1997-07 Status: 2003-03Brewing sequenceAfter having pressed the product key:1. Coffee is ground and falls
6-7Service instructions bremer VIVA, issued 1997-07 Status: 2003-03Filter and plunger position for espressoEspressoNeedle cushion and perforateddisc p
1Service instructions bremer VIVA, issued 1997-07 Status: 2003-031. Table of Contents PageIndex (after Table of Contents) A2. Dimensions, table cut−ou
6-8Service instructions bremer VIVA, issued 1997-07 Status: 2003-03Notes CleaningIf the automatic cleaning sequence is interrupted by switching off th
6-9Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.2.3 Checking/adjusting the brewing unit. Carry out functional test.. Subject all
6-10Service instructions bremer VIVA, issued 1997-07 Status: 2003-03Checking 36 mm measurement- Permissible deviation +/-0.5 mm.- Above 36 mm: ”lower
6-11Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.2.4 Removing the brewing unit from the machineDisconnect machine from mains,shut
6-12Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.2.5 Replacing worn parts of the ”upper plunger”. Remove brewing unit (see sec-ti
6-13Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.2.6 Replacing worn parts of the ”lower plunger”. Remove brewing unit (see sec-ti
6-14Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.2.7 Replacing the wiper profile. Remove brewing unit (see sec-tion 6.2.4).. Unsc
6-15Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.2.9 Test run of brewing unitCarry out a test run after- removing and reinstallin
6-16Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.2.11 Quick coupling/teflon hoseRemoving the teflon hose. Push teflon hose in the
6-17Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.3 Reference point switch and encoder (photelectric barrier)6.3.1 Operation of re
2Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.2 Brewing unit 6-5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6-18Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.4 Grounds container and microswitch6.4.1 OperationThe parameter ”Grounds contain
6-19Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.5 Pressure regulator6.5.1 OperationThe pressure regulator is set to 2.6 bar.To e
6-20Service instructions bremer VIVA, issued 1997-07 Status: 2003-03Cleaning the pressure regulatorcartridgeDisconnect machine from mains!. Shut off w
6-21Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.6 Flow sensor6.6.1 OperationThe water flowing in through the nozzlecauses the im
6-22Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.7 Motor-driven pumpThe motor-driven pump is required for the coffee specialities
6-23Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.7.3 Removing the pump head / removing the motor-driven pumpDisconnect machine fr
6-24Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.7.4 Technical data of motor-driven pumpVoltage: 230 V AC 50/60 Hz Nominal output
6-25Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.8 Brewing water boiler6.8.1 Operation of brewing water boiler (installed on left
6-26Service instructions bremer VIVA, issued 1997-07 Status: 2003-03Single-pole bimetallic safetythermostat (page 6-33)Cold water inletSolenoid valve
6-27Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.8.2 Temperature settings for brewing water boilerThese are adjusted via the para
3Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.10 Removing the brewing water or hot water/steam boiler 6-32. . . . . . . . . . . 6
6-28Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.9 Hot water/steam boiler6.9.1 Operation of hot water/steam boiler (installed on
6-29Service instructions bremer VIVA, issued 1997-07 Status: 2003-03Ventilation of the hot water / steam boilerVentilation during the heating process:
6-30Service instructions bremer VIVA, issued 1997-07 Status: 2003-03NTC temperature sensor (page 6-36)Cold water inletSingle-pole bimetallic safety th
6-31Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.9.2 Maintenance interval for hot water/steam boilerDepends on- water hardness- f
6-32Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.10 Removing the brewing water or hot water/steam boilerThe boilers must be repla
6-33Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.11 Safety thermostat (bimetallic thermostat)Temperature limit: 132°C. Contacts o
6-34Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.12 Safety valvesSafety valves serve to prevent pressurised fluid systems from ex
6-35Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.13 Solenoid valves2/2-way valve- Y2 for supplying cold water to hotwater/steam b
6-36Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.14 NTC temperature sensorNTC temperature sensor- in hot water/steam boiler: for
6-37Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.14.2 Checking/replacing the NTC temperature sensorIn the event of a fault, the f
4Service instructions bremer VIVA, issued 1997-07 Status: 2003-038.2 Uninstalling/changing the fuses 8-1. . . . . . . . . . . . . . . . . . . . . . .
6-38Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.15 Air valve (removed at 30.8.99)6.15.1 Operation of air valveMounted on hot wat
6-39Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.16 Pressure switch6.16.1 Operation of pressure switchMounted on hot water/steam
6-40Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.16.2 Checking/maintenance of pressure switchChecking. Start up machine.. Connect
6-41Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.17 Check valveThe check valves prevent the water fromflowing back out of the bre
6-42Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.18 Electrode for hot water/steam boiler water level6.18.1 OperationAn alternatin
6-43Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.19 Coffee dispenser with frother head6.19.1 OperationThe prepared coffee flows t
6-44Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.19.2 Adjusting the milk froth dispenserDepending on the sort of milk or its qual
6-45Service instructions bremer VIVA, issued 1997-07 Status: 2003-036.19.3 Maintenance / cleaning / replacement of O-rings. Pull down holder guide.. U
6-1Serviceanleitung bremer VIVA, Erst. 2004−3−96.20 Emptying of Boilers (VIVA TRAIN)This function serves the VIVA coffee machines execution TRAIN for
7-1Service instructions bremer VIVA, issued 1997-07 Status: 2003-037. Menu control7.1 Settings/displaysThe following are described in the operating in
AService instructions bremer VIVA, issued 1997-07 Status: 2003-03IndexAAdjustmentBrewing time for each article, 7-2Grinding fineness, 6-1Hot water met
7-2Service instructions bremer VIVA, issued 1997-07 Status: 2003-037.2 Service menu (1st gen.)Summing counter!!! STANDBY !!!Brewed waterTemperature: 0
7-3Service instructions bremer VIVA, issued 1997-07 Status: 2003-03Steam boilerpresent: NOVoltage: 230V_Hot water:measuredActivate controller for ho
7-4Service instructions bremer VIVA, issued 1997-07 Status: 2003-037.2.1 Exit service menuhot waterdosageAccessing and quittingthe service menuAdding
8-1Service instructions bremer VIVA, issued 1997-07 Status: 2003-038. Control system8.1 Arrangement of fuses and relaysF4F2F3F1K6K5K4K3K2K1Relay forbo
8-2Service instructions bremer VIVA, issued 1997-07 Status: 2003-038.3 Removing the relaysRemoval1. Press down lever and hold firmly.2. Slide up and d
8-3Service instructions bremer VIVA, issued 1997-07 Status: 2003-038.5 Circuit diagrams/function diagramsControl system function diagram identity no.−
9-1Service instructions bremer VIVA, issued 1997-07 Status: 2003-039. Faults and remedies9.1 Machine error code displayErrorcodeError Cause of error01
9-2Service instructions bremer VIVA, issued 1997-07 Status: 2003-039.2 Faults and remediesFault/error Check Cause Remedy
9-3Service instructions bremer VIVA, issued 1997-07 Status: 2003-039.3 Special tools/lubricantsRecommended special toolsHexagon/ball−head screwdriver,
10-1Service instructions bremer VIVA, issued 1997-07 Status: 2003-0310. Miscellaneous
BService instructions bremer VIVA, issued 1997-07 Status: 2003-03Display of error codes, 9-1DisplaysNumber of completed brewing, 7-3Software version,
10-2Service instructions bremer VIVA, issued 1997-07 Status: 2003-0310.1 Water boiler (VIVA au lait, VIVA Barista, Europa)Cold water inletSafety valve
10-3Service instructions bremer VIVA, issued 1997-07 Status: 2003-0310.1.1 Technical data: water boiler (VIVA au lait, Barista)Voltage heating body: 2
10-4Service instructions bremer VIVA, issued 1997-07 Status: 2003-03Cold water inletBorings must not be closed!Reason: Cold water is lead to thetemper
10-5Service instructions bremer VIVA, issued 1997-07 Status: 2003-0310.3 HW Steam boiler (VIVA McD)approx. 40ElectrodeSteam discharge I2Temperature se
10-6Service instructions bremer VIVA, issued 1997-07 Status: 2003-0310.3.1 Technical data HW Steam boiler (VIVA McD)Voltage heating body: 230V AC Flui
10-7Service instructions bremer VIVA, issued 1997-07 Status: 2003-0310.4 Water boiler (VIVA 220V 3.0 kW UL, America)Cold water inletSafety valve 150Ps
10-8Service instructions bremer VIVA, issued 1997-07 Status: 2003-0310.4.1 Technical data: water boiler (VIVA 220V 3.0 kW UL, America)Voltage heating
10-9Service instructions bremer VIVA, issued 1997-07 Status: 2003-0310.5 Hot water steam boiler (VIVA Barista UL, America)Cold water inletSafety valve
10-10Service instructions bremer VIVA, issued 1997-07 Status: 2003-0310.5.1 Technical data HW Steam boiler (VIVA Barista UL, America)Voltage heating b
10-11Service instructions bremer VIVA, issued 1997-07 Status: 2003-0310.5.3 Pressure switch HW Steam boiler (VIVA Barista UL, America)sealed with Loct